<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Majengo Group Engineering</title>
	<atom:link href="https://www.majengoengineering.com/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.majengoengineering.com/</link>
	<description>Prevention is better than cure</description>
	<lastBuildDate>Tue, 07 Dec 2021 18:25:38 +0000</lastBuildDate>
	<language>en-ZA</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.majengoengineering.com/wp-content/uploads/2021/09/MAJENGO-favicon-150x150.png</url>
	<title>Majengo Group Engineering</title>
	<link>https://www.majengoengineering.com/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Weld Procedure Qualification And Weld Qualifications.</title>
		<link>https://www.majengoengineering.com/weld-procedure-qualification-and-weld-qualifications/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 04 Dec 2021 11:30:20 +0000</pubDate>
				<category><![CDATA[METALLURGY]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=2117</guid>

					<description><![CDATA[<p>Through our qualified and experienced welding inspectors we do assist in the preparation and the qualification of manufacturing weld procedures to various national and international specifications. Weld procedure qualifications: &#8211; Witness welding of test piece &#8211; Mechanical testing and radiographic testing of the test piece as per code requirements. &#8211; Drafting and approving weld procedure [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/weld-procedure-qualification-and-weld-qualifications/">Weld Procedure Qualification And Weld Qualifications.</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Through our qualified and experienced welding inspectors we do assist in the preparation and the qualification of manufacturing weld procedures to various national and international specifications.</p>



<h3 class="wp-block-heading"><strong>Weld procedure qualifications:</strong></h3>



<p>&#8211; Witness welding of test piece</p>



<p>&#8211; Mechanical testing and radiographic testing of the test piece as per code requirements.</p>



<p>&#8211; Drafting and approving weld procedure qualifications according to various code such as ASME VIII, AWS D1.1, EN 14025 and 9606</p>



<p>&#8211; Drafting of qualified and pre-qualified procedures.</p>



<h3 class="wp-block-heading"><strong>Welder qualifications:</strong></h3>



<p>-Witness welding of test piece&nbsp;</p>



<p>-Mechanical testing and/or radiography of test piece as per code requirements</p>



<p>-Drafting of welder qualification certificates according to codes such as ASME VIII, AWS D1.1, EN 14025 and 9606.</p>
<p>The post <a href="https://www.majengoengineering.com/weld-procedure-qualification-and-weld-qualifications/">Weld Procedure Qualification And Weld Qualifications.</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Field Spectroscopy- Spark Testing</title>
		<link>https://www.majengoengineering.com/field-spectroscopy-spark-testing/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 04 Dec 2021 11:19:51 +0000</pubDate>
				<category><![CDATA[Conventional NDT]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=2114</guid>

					<description><![CDATA[<p>Automated spark testing has been developed to remove the reliance upon operator skill and experience thereby increasing reliability. The system relies upon spectroscopy, spectrometry and other methods to” observe” the spark pattern. It has been found that this system can determine the difference between two materials that give off sparks that are indistinguishable to the  [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/field-spectroscopy-spark-testing/">Field Spectroscopy- Spark Testing</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Automated spark testing has been developed to remove the reliance upon operator skill and experience thereby increasing reliability. The system relies upon spectroscopy, spectrometry and other methods to” observe” the spark pattern. It has been found that this system can determine the difference between two materials that give off sparks that are indistinguishable to the  human eye. Spark testing involves the use of a field portable electronic instrument specifically designed to analyse metals, measure and quantify the chemical content. The instrument gives elemental content of metallic and non-metallic compounds which make up  the material under analysis and will give the percentage content of the elements present.</p>
<p>The post <a href="https://www.majengoengineering.com/field-spectroscopy-spark-testing/">Field Spectroscopy- Spark Testing</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Lighting  Column  Inspections</title>
		<link>https://www.majengoengineering.com/lighting-column-inspections/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 06 Nov 2021 11:48:21 +0000</pubDate>
				<category><![CDATA[Electrical maintenance]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1543</guid>

					<description><![CDATA[<p>Are you concerned about your lighting column&#8217;s structural integrity? Majengo Group Engineering offers effective on-site inspection and testing services to the street industry that cover all areas as being at risk to corrosion. Test where&#160; it matters. The unique relative loss of section system was developed specially to locate and quantify corrosion of steel columns [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/lighting-column-inspections/">Lighting  Column  Inspections</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Are you concerned about your lighting column&#8217;s structural integrity?</p>



<p>Majengo Group Engineering offers effective on-site inspection and testing services to the street industry that cover all areas as being at risk to corrosion.</p>



<p>Test where&nbsp; it matters.</p>



<p>The unique relative loss of section system was developed specially to locate and quantify corrosion of steel columns that cannot be identified by visual inspection .</p>



<p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;eg; Internal and external surfaces of the buried section of the root,and internal corrosion of the base and hot swaged joint .</p>



<p>The relative loss of section technique is a&nbsp; dry coupled system that will provide a cost efficient assessment of the column. The result obtained estimates the percentage loss of section allowed to be classified (1 to 5) for either replacement or retesting at scheduled intervals. An electronic reporting procedure enables test results to be downloaded directly into the client&#8217;s inventory.</p>



<p>The Institute of Lighting Engineers (UK) has approved the RLS system for structural testing of steel lighting columns. For a complete cost&nbsp; effective inspection and testing service that has been employed by many authorities and contractors in the uk and overseas . Then Relative loss of section has to be the obvious choice.</p>
<p>The post <a href="https://www.majengoengineering.com/lighting-column-inspections/">Lighting  Column  Inspections</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Group Relamping</title>
		<link>https://www.majengoengineering.com/group-relamping/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 06 Nov 2021 11:46:08 +0000</pubDate>
				<category><![CDATA[Electrical maintenance]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1541</guid>

					<description><![CDATA[<p>Group Relamping is a planned maintenance strategy that entails replacing all lamps in a system at scheduled intervals when lamp lumen depreciation and the lamp failure rate make it economical to do so. Majengo Group will create and maintain a database that will include quantity and type of lamps in the various plants, the date [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/group-relamping/">Group Relamping</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Group Relamping is a planned maintenance strategy that entails replacing all lamps in a system at scheduled intervals when lamp lumen depreciation and the lamp failure rate make it economical to do so. Majengo Group will<strong> </strong>create and maintain a database that will include quantity and type of lamps in the various plants, the date of group relamping , number of spot relamping between group relamping and next scheduled relamping date.</p>



<p>At 70% of rated life of the lamp on when 10% of the previous group relamping are logged to have failed appeared to be the&nbsp; most economical range to conduct group relamping. Our calculations are based on these statistics.</p>



<ul class="wp-block-list"><li>Fixture Cleaning</li></ul>



<p>Periodic fixture cleaning ensures that all diffusers allow the maximum light output.</p>



<ul class="wp-block-list"><li>Inspection</li></ul>



<p>Group Relamping will allow us the opportunity to carry out detailed inspections. Through this we will be able to identify defects such as cracked lamp holders and loose wiring.</p>
<p>The post <a href="https://www.majengoengineering.com/group-relamping/">Group Relamping</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Planned Lighting Maintenance.</title>
		<link>https://www.majengoengineering.com/planned-lighting-maintenance/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 06 Nov 2021 11:41:56 +0000</pubDate>
				<category><![CDATA[Electrical maintenance]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1539</guid>

					<description><![CDATA[<p>A practice referred to as spot relamping is used at most industrial facilities around the world,operations identifies which lights have failed and submit a work request to the maintenance department.The planner/ scheduler convert it to a work order and this is submitted to Majengo Group Engineering for action. It is then handed over to the [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/planned-lighting-maintenance/">Planned Lighting Maintenance.</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>A practice referred to as spot relamping is used at most industrial facilities around the world,operations identifies which lights have failed and submit a work request to the maintenance department.The planner/ scheduler convert it to a work order and this is submitted to Majengo Group Engineering for action. It is then handed over to the lighting team for replacement and after that ,a report.</p>



<p>This practice also leads to poor lighting levels, as the lamp is only replaced when it fails. However, as all lamps age and near the end of their life, they can produce less and less light. This is referred to as planned lighting maintenance and includes three main aspects:</p>



<ul class="wp-block-list"><li>Group Relamping.</li></ul>



<ul class="wp-block-list"><li>Fixture Cleaning .</li></ul>



<ul class="wp-block-list"><li>Inspection.</li></ul>



<p>A planned lighting maintenance programme&nbsp; will :</p>



<ul class="wp-block-list"><li>Reduce labour costs</li></ul>



<ul class="wp-block-list"><li>Reduce the cost of lamps purchased in large quantities.</li></ul>



<ul class="wp-block-list"><li>Produce high levels over the life of the lighting system.</li></ul>



<ul class="wp-block-list"><li>Generate lighting upgrade opportunities such as reduced output energy saving lamps.</li></ul>



<ul class="wp-block-list"><li>Ensure proper inspection and upkeep of the lighting system.</li></ul>



<p>Majengo Group Engineering can provide a planned lighting maintenance programme that will improve and ensure consistent recommended light levels and at the same time reduce costs through improved efficiencies of labour resources and through purchasing lamps in large quantities.</p>
<p>The post <a href="https://www.majengoengineering.com/planned-lighting-maintenance/">Planned Lighting Maintenance.</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Earth Leakage Testing</title>
		<link>https://www.majengoengineering.com/earth-leakage-testing/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 06 Nov 2021 11:35:03 +0000</pubDate>
				<category><![CDATA[Electrical inspection]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1536</guid>

					<description><![CDATA[<p>Earth Leakage units have probably saved thousands of lives around the world, however if they are not regularly tested there is no way of knowing if they will function when needed. Around the world , best practice dictates that all earth leakage units should be tested periodically based on whether they are provided protection for [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/earth-leakage-testing/">Earth Leakage Testing</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Earth Leakage units have probably saved thousands of lives around the world, however if they are not regularly tested there is no way of knowing if they will function when needed.</p>



<p>Around the world , best practice dictates that all earth leakage units should be tested periodically based on whether they are provided protection for wet or dry areas. We offer the service of both push button and function testing to ensure safety and minimize costs.</p>
<p>The post <a href="https://www.majengoengineering.com/earth-leakage-testing/">Earth Leakage Testing</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fixed electrical Installation Inspections</title>
		<link>https://www.majengoengineering.com/fixed-electrical-installation-inspections/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 06 Nov 2021 11:34:19 +0000</pubDate>
				<category><![CDATA[Electrical inspection]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1534</guid>

					<description><![CDATA[<p>As per Regulations, The&#160; employer has the duty of care to ensure that the electrical installations, machineries and appliances are inspected and maintained to ensure that they are safe. We believe that every installation should&#160; be inspected on a regular basis, however the frequency will vary depending on the type of installation. An office may [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/fixed-electrical-installation-inspections/">Fixed electrical Installation Inspections</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>As per Regulations, The&nbsp; employer has the duty of care to ensure that the electrical installations, machineries and appliances are inspected and maintained to ensure that they are safe.</p>



<p>We believe that every installation should&nbsp; be inspected on a regular basis, however the frequency will vary depending on the type of installation. An office may need to be inspected once every 10 years while a workshop may need it every 5 years.</p>
<p>The post <a href="https://www.majengoengineering.com/fixed-electrical-installation-inspections/">Fixed electrical Installation Inspections</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Temporary Electrical Installation Inspections</title>
		<link>https://www.majengoengineering.com/temporary-electrical-installation-inspections/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 06 Nov 2021 11:30:00 +0000</pubDate>
				<category><![CDATA[Electrical inspection]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1530</guid>

					<description><![CDATA[<p>The temporary electrical installations are very dangerous due their nature of being temporary. We have found that most temporary electrical installations pose a safety risk to all that are using them. The recent changes to the electrical Regulations relating to the construction sites state that: All temporary electrical inspections must be inspected every week by [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/temporary-electrical-installation-inspections/">Temporary Electrical Installation Inspections</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>The temporary electrical installations are very dangerous due their nature of being temporary. We have found that most temporary electrical installations pose a safety risk to all that are using them.</p>



<p>The recent changes to the electrical Regulations relating to the construction sites state that:</p>



<p>All temporary electrical inspections must be inspected every week by a competent person</p>
<p>The post <a href="https://www.majengoengineering.com/temporary-electrical-installation-inspections/">Temporary Electrical Installation Inspections</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Portable electrical appliance testing</title>
		<link>https://www.majengoengineering.com/portable-electrical-appliance-testing/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 06 Nov 2021 11:27:38 +0000</pubDate>
				<category><![CDATA[Electrical inspection]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1525</guid>

					<description><![CDATA[<p>The institution of electrical engineers code of practice for in-service inspection and testing of electrical equipment state that: The following electrical equipments should be inspected on Regular basis, Portable electric tools Fixed electrical equipment . eg: Fridges, Water heaters Portable electrical equipment.&#160; eg: Kettles, toasters. Extension leads Majengo Group Engineering has the complete system needed [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/portable-electrical-appliance-testing/">Portable electrical appliance testing</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<h4 class="wp-block-heading"><strong>The institution of electrical engineers code of practice for in-service inspection and testing of electrical equipment state that:</strong></h4>



<p>The following electrical equipments should be inspected on Regular basis,</p>



<ul class="wp-block-list"><li>Portable electric tools</li><li>Fixed electrical equipment . eg: Fridges, Water heaters</li><li>Portable electrical equipment.&nbsp; eg: Kettles, toasters.</li><li>Extension leads</li></ul>



<p>Majengo Group Engineering has the complete system needed to manage the inspection and maintenance of the above equipment. We make use of the seaward supernova portable appliance tester (PAT) linked to our electronic database.</p>



<p>The advantage of PAT is that all the following tests can be carried out using one test instrument,</p>



<ul class="wp-block-list"><li>Earth Continuity test.</li><li>Earth Bond test.</li><li>Insulation Resistance test.</li><li>Leakage test.</li><li>Flash test.</li></ul>



<p>Our database monitors all equipment and will email the client to inform them that their equipment will soon be re-inspected. Again not all equipment needs to be re-inspected every three months. The type of equipment will decide the Re-inspection date ,and this can vary from three to 24 months.</p>
<p>The post <a href="https://www.majengoengineering.com/portable-electrical-appliance-testing/">Portable electrical appliance testing</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Heat Treatment</title>
		<link>https://www.majengoengineering.com/heat-treatment/</link>
		
		<dc:creator><![CDATA[Francis]]></dc:creator>
		<pubDate>Sat, 23 Oct 2021 10:28:26 +0000</pubDate>
				<category><![CDATA[Conventional NDT]]></category>
		<guid isPermaLink="false">https://www.majengoengineering.com/?p=1335</guid>

					<description><![CDATA[<p>Heat treatment of steels and other suitable metals involves the heating of the items to specific temperatures where desired metallurgical changes to microstructure takes place . These temperatures can range from as low as 250°C&#160; on temper hardened steels to as high as 1150°C on certain tool steels. The main purpose of heat treatment is [&#8230;]</p>
<p>The post <a href="https://www.majengoengineering.com/heat-treatment/">Heat Treatment</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p>Heat treatment of steels and other suitable metals involves the heating of the items to specific temperatures where desired metallurgical changes to microstructure takes place . These temperatures can range from as low as 250°C&nbsp; on temper hardened steels to as high as 1150°C on certain tool steels. The main purpose of heat treatment is to obtain the desired hardness, Tensile strength, Ductility, internal stress levels and Microstructure in the steel.</p>
<p>The post <a href="https://www.majengoengineering.com/heat-treatment/">Heat Treatment</a> appeared first on <a href="https://www.majengoengineering.com">Majengo Group Engineering</a>.</p>
]]></content:encoded>
					
		
		